| Name | Data Type | Qualifiers |
| Name | Data Type | Value | Scope | Flavors |
| ActiveInputVoltage | uint16 |
| Description | string | ActiveInputVoltage indicates which input voltage range is currently in use. Range 1, 2 or both can be specified using the values 3, 4 or 5, respectively. If the Supply is not currently drawing power, the value 6 ("Neither") can be specified. This information is necessary in the case of a UPS, a subclass of PowerSupply. | None | TRANSLATABLE= true |
| MappingStrings | string | MIF.DMTF|Power Supply|004 | None | None |
| ValueMap | string | 1, 2, 3, 4, 5, 6 | None | None |
| Values | string | Other, Unknown, Range 1, Range 2, Both, Neither | None | TRANSLATABLE= true |
| IsSwitchingSupply | boolean |
| Description | string | Boolean indicating that the PowerSupply is a switching (vs linear) supply. | None | TRANSLATABLE= true |
| Range1InputFrequencyHigh | uint32 |
| Description | string | The frequency (in Hertz) at the high end of this PowerSupply's Input Frequency Range 1. A value of zero implies DC. | None | TRANSLATABLE= true |
| MappingStrings | string | MIF.DMTF|Power Supply|004 | None | None |
| Units | string | Hertz | None | TRANSLATABLE= true |
| Range1InputFrequencyLow | uint32 |
| Description | string | The frequency (in Hertz) at the low end of this PowerSupply's Input Frequency Range 1. A value of zero implies DC. | None | TRANSLATABLE= true |
| MappingStrings | string | MIF.DMTF|Power Supply|004 | None | None |
| Units | string | Hertz | None | TRANSLATABLE= true |
| Range1InputVoltageHigh | uint32 |
| Description | string | The high voltage of Input Voltage Range 1 for this PowerSupply, in millivolts. A value of 0 denotes 'unknown'. | None | TRANSLATABLE= true |
| MappingStrings | string | MIF.DMTF|Power Supply|004 | None | None |
| Units | string | MilliVolts | None | TRANSLATABLE= true |
| Range1InputVoltageLow | uint32 |
| Description | string | The low voltage of Input Voltage Range 1 for this PowerSupply, in millivolts. A value of 0 denotes 'unknown'. | None | TRANSLATABLE= true |
| MappingStrings | string | MIF.DMTF|Power Supply|004 | None | None |
| Units | string | MilliVolts | None | TRANSLATABLE= true |
| Range2InputFrequencyHigh | uint32 |
| Description | string | The frequency (in Hertz) at the high end of this PowerSupply's Input Frequency Range 2. A value of zero implies DC. | None | TRANSLATABLE= true |
| MappingStrings | string | MIF.DMTF|Power Supply|004 | None | None |
| Units | string | Hertz | None | TRANSLATABLE= true |
| Range2InputFrequencyLow | uint32 |
| Description | string | The frequency (in Hertz) at the low end of this PowerSupply's Input Frequency Range 2. A value of zero implies DC. | None | TRANSLATABLE= true |
| MappingStrings | string | MIF.DMTF|Power Supply|004 | None | None |
| Units | string | Hertz | None | TRANSLATABLE= true |
| Range2InputVoltageHigh | uint32 |
| Description | string | The high voltage of Input Voltage Range 2 for this PowerSupply, in millivolts. A value of 0 denotes 'unknown'. | None | TRANSLATABLE= true |
| MappingStrings | string | MIF.DMTF|Power Supply|004 | None | None |
| Units | string | MilliVolts | None | TRANSLATABLE= true |
| Range2InputVoltageLow | uint32 |
| Description | string | The low voltage of Input Voltage Range 2 for this PowerSupply, in millivolts. A value of 0 denotes 'unknown'. | None | TRANSLATABLE= true |
| MappingStrings | string | MIF.DMTF|Power Supply|004 | None | None |
| Units | string | MilliVolts | None | TRANSLATABLE= true |
| TotalOutputPower | uint32 |
| Description | string | Represents the total output power of the PowerSupply in milliWatts. 0 denotes 'unknown'. | None | TRANSLATABLE= true |
| MappingStrings | string | MIF.DMTF|Power Supply|004 | None | None |
| Units | string | MilliWatts | None | TRANSLATABLE= true |
| TypeOfRangeSwitching | uint16 |
| Description | string | TypeOfRangeSwitching describes the kind of input voltage range switching implemented in this PowerSupply. For example, autoswitching can be specified (value=4). | None | TRANSLATABLE= true |
| MappingStrings | string | MIF.DMTF|Power Supply|004 | None | None |
| ValueMap | string | 1, 2, 3, 4, 5, 6 | None | None |
| Values | string | Other, Unknown, Manual, Autoswitch, Wide Range, Not Applicable | None | TRANSLATABLE= true |