Class CIM_UninterruptiblePowerSupply
extends CIM_PowerSupply

Capabilities and management of an UninterruptiblePowerSupply. The properties of the UPS Device indicate when incoming power is trimmed or boosted, and the aggregated information of the batteries, generators, etc. that comprise the Device. These individual components (for example, multiple batteries) can also be independently modeled and associated with the UPS.

Class Hierarchy

CIM_ManagedElement
   |
   +--CIM_ManagedSystemElement
   |
   +--CIM_LogicalElement
   |
   +--CIM_LogicalDevice
   |
   +--CIM_PowerSupply
   |
   +--CIM_UninterruptiblePowerSupply

Direct Known Subclasses

None.

Class Qualifiers

NameData TypeValueScopeFlavors
DescriptionstringCapabilities and management of an UninterruptiblePowerSupply. The properties of the UPS Device indicate when incoming power is trimmed or boosted, and the aggregated information of the batteries, generators, etc. that comprise the Device. These individual components (for example, multiple batteries) can also be independently modeled and associated with the UPS.None TRANSLATABLE= true

Local Class Properties

NameData TypeQualifiers
NameData TypeValueScopeFlavors
EstimatedChargeRemaininguint16
DescriptionstringAn estimate of the percentage of full charge remaining for a UPS (that uses battery technology).None TRANSLATABLE= true
GaugebooleantrueNone None
MappingStringsstringMIF.DMTF|UPS Battery|001.4None None
UnitsstringPercentNone TRANSLATABLE= true
EstimatedRunTimeuint32
DescriptionstringEstimatedRunTime is an estimate in minutes of the time to battery, generator, ... depletion under the present load conditions if the utility power is off, or lost and remains off.None TRANSLATABLE= true
MappingStringsstringMIF.DMTF|UPS Battery|001.3None None
UnitsstringMinutesNone TRANSLATABLE= true
Range1InputVoltageHighuint32
DescriptionstringIf the voltage (in millivolts) rises above the value specified by Range1InputVoltageHigh, the UPS will compensate by trimming the voltage. A value of 0 indicates that the voltage at which trimming occurs is 'unknown'.None TRANSLATABLE= true
MappingStringsstringMIF.DMTF|Power Supply|004None None
OverridestringRange1InputVoltageHighNone OVERRIDABLE= false
UnitsstringMilliVoltsNone TRANSLATABLE= true
Range1InputVoltageLowuint32
DescriptionstringIf the voltage (in millivolts) drops below the value specified by Range1InputVoltageLow, the UPS will compensate by boosting the voltage using its power source(s). A value of 0 indicates that the voltage at which boosting occurs is 'unknown'.None TRANSLATABLE= true
MappingStringsstringMIF.DMTF|Power Supply|004None None
OverridestringRange1InputVoltageLowNone OVERRIDABLE= false
UnitsstringMilliVoltsNone TRANSLATABLE= true
Range2InputVoltageHighuint32
DescriptionstringIf the voltage (in millivolts) rises above the value specified by Range2InputVoltageHigh, the UPS will compensate by trimming the voltage. A value of 0 indicates that the voltage at which trimming occurs is 'unknown'.None TRANSLATABLE= true
MappingStringsstringMIF.DMTF|Power Supply|004None None
OverridestringRange2InputVoltageHighNone OVERRIDABLE= false
UnitsstringMilliVoltsNone TRANSLATABLE= true
Range2InputVoltageLowuint32
DescriptionstringIf the voltage (in millivolts) drops below the value specified by Range2InputVoltageLow, the UPS will compensate by boosting the voltage using its power source(s). A value of 0 indicates that the voltage at which boosting occurs is 'unknown'.None TRANSLATABLE= true
MappingStringsstringMIF.DMTF|Power Supply|004None None
OverridestringRange2InputVoltageLowNone OVERRIDABLE= false
UnitsstringMilliVoltsNone TRANSLATABLE= true
RemainingCapacityStatusuint16
DescriptionstringThe indication of the capacity remaining in the UPS' batteries, generator, ... A value of "Normal" (2) indicates that the remaining estimated minutes of run-time is greater than the UPS' defined 'low power' state (typically two minutes). A value of "Low" (3) indicates that the remaining estimated minutes of run-time is less than or equal to the UPS' defined 'low power' state. A value of "Depleted" (4) indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent).None TRANSLATABLE= true
MappingStringsstringMIF.DMTF|UPS Battery|001.1None None
ValueMapstring1, 2, 3, 4None None
ValuesstringUnknown, Normal, Low, DepletedNone TRANSLATABLE= true
TimeOnBackupuint32
DescriptionstringTimeOnBackup indicates the elapsed time in seconds since the UPS last switched to battery power, generator, ... Or, the time since the UPS was last restarted, whichever is less. Zero shall be returned if the UPS is 'on line'.None TRANSLATABLE= true
MappingStringsstringMIF.DMTF|UPS Battery|001.2None None
UnitsstringSecondsNone TRANSLATABLE= true

Inherited Properties

NameData TypeClass Origin
ActiveInputVoltageuint16CIM_PowerSupply
Availabilityuint16CIM_LogicalDevice
CaptionstringCIM_ManagedElement
CreationClassNamestringCIM_LogicalDevice
DescriptionstringCIM_ManagedElement
DeviceIDstringCIM_LogicalDevice
ErrorClearedbooleanCIM_LogicalDevice
ErrorDescriptionstringCIM_LogicalDevice
InstallDatedatetimeCIM_ManagedSystemElement
IsSwitchingSupplybooleanCIM_PowerSupply
LastErrorCodeuint32CIM_LogicalDevice
MaxQuiesceTimeuint64CIM_LogicalDevice
NamestringCIM_ManagedSystemElement
PowerManagementSupportedbooleanCIM_LogicalDevice
PowerOnHoursuint64CIM_LogicalDevice
Range1InputFrequencyHighuint32CIM_PowerSupply
Range1InputFrequencyLowuint32CIM_PowerSupply
Range2InputFrequencyHighuint32CIM_PowerSupply
Range2InputFrequencyLowuint32CIM_PowerSupply
StatusstringCIM_ManagedSystemElement
StatusInfouint16CIM_LogicalDevice
SystemCreationClassNamestringCIM_LogicalDevice
SystemNamestringCIM_LogicalDevice
TotalOutputPoweruint32CIM_PowerSupply
TotalPowerOnHoursuint64CIM_LogicalDevice
TypeOfRangeSwitchinguint16CIM_PowerSupply