Class CIM_PowerSupply
extends CIM_LogicalDevice

Capabilities and management of the PowerSupply LogicalDevice.

Class Hierarchy

CIM_ManagedElement
   |
   +--CIM_ManagedSystemElement
   |
   +--CIM_LogicalElement
   |
   +--CIM_LogicalDevice
   |
   +--CIM_PowerSupply

Direct Known Subclasses

CIM_UninterruptiblePowerSupply

Class Qualifiers

NameData TypeValueScopeFlavors
DescriptionstringCapabilities and management of the PowerSupply LogicalDevice.None TRANSLATABLE= true

Local Class Properties

NameData TypeQualifiers
NameData TypeValueScopeFlavors
ActiveInputVoltageuint16
DescriptionstringActiveInputVoltage indicates which input voltage range is currently in use. Range 1, 2 or both can be specified using the values 3, 4 or 5, respectively. If the Supply is not currently drawing power, the value 6 ("Neither") can be specified. This information is necessary in the case of a UPS, a subclass of PowerSupply.None TRANSLATABLE= true
MappingStringsstringMIF.DMTF|Power Supply|004None None
ValueMapstring1, 2, 3, 4, 5, 6None None
ValuesstringOther, Unknown, Range 1, Range 2, Both, NeitherNone TRANSLATABLE= true
IsSwitchingSupplyboolean
DescriptionstringBoolean indicating that the PowerSupply is a switching (vs linear) supply.None TRANSLATABLE= true
Range1InputFrequencyHighuint32
DescriptionstringThe frequency (in Hertz) at the high end of this PowerSupply's Input Frequency Range 1. A value of zero implies DC.None TRANSLATABLE= true
MappingStringsstringMIF.DMTF|Power Supply|004None None
UnitsstringHertzNone TRANSLATABLE= true
Range1InputFrequencyLowuint32
DescriptionstringThe frequency (in Hertz) at the low end of this PowerSupply's Input Frequency Range 1. A value of zero implies DC.None TRANSLATABLE= true
MappingStringsstringMIF.DMTF|Power Supply|004None None
UnitsstringHertzNone TRANSLATABLE= true
Range1InputVoltageHighuint32
DescriptionstringThe high voltage of Input Voltage Range 1 for this PowerSupply, in millivolts. A value of 0 denotes 'unknown'.None TRANSLATABLE= true
MappingStringsstringMIF.DMTF|Power Supply|004None None
UnitsstringMilliVoltsNone TRANSLATABLE= true
Range1InputVoltageLowuint32
DescriptionstringThe low voltage of Input Voltage Range 1 for this PowerSupply, in millivolts. A value of 0 denotes 'unknown'.None TRANSLATABLE= true
MappingStringsstringMIF.DMTF|Power Supply|004None None
UnitsstringMilliVoltsNone TRANSLATABLE= true
Range2InputFrequencyHighuint32
DescriptionstringThe frequency (in Hertz) at the high end of this PowerSupply's Input Frequency Range 2. A value of zero implies DC.None TRANSLATABLE= true
MappingStringsstringMIF.DMTF|Power Supply|004None None
UnitsstringHertzNone TRANSLATABLE= true
Range2InputFrequencyLowuint32
DescriptionstringThe frequency (in Hertz) at the low end of this PowerSupply's Input Frequency Range 2. A value of zero implies DC.None TRANSLATABLE= true
MappingStringsstringMIF.DMTF|Power Supply|004None None
UnitsstringHertzNone TRANSLATABLE= true
Range2InputVoltageHighuint32
DescriptionstringThe high voltage of Input Voltage Range 2 for this PowerSupply, in millivolts. A value of 0 denotes 'unknown'.None TRANSLATABLE= true
MappingStringsstringMIF.DMTF|Power Supply|004None None
UnitsstringMilliVoltsNone TRANSLATABLE= true
Range2InputVoltageLowuint32
DescriptionstringThe low voltage of Input Voltage Range 2 for this PowerSupply, in millivolts. A value of 0 denotes 'unknown'.None TRANSLATABLE= true
MappingStringsstringMIF.DMTF|Power Supply|004None None
UnitsstringMilliVoltsNone TRANSLATABLE= true
TotalOutputPoweruint32
DescriptionstringRepresents the total output power of the PowerSupply in milliWatts. 0 denotes 'unknown'.None TRANSLATABLE= true
MappingStringsstringMIF.DMTF|Power Supply|004None None
UnitsstringMilliWattsNone TRANSLATABLE= true
TypeOfRangeSwitchinguint16
DescriptionstringTypeOfRangeSwitching describes the kind of input voltage range switching implemented in this PowerSupply. For example, autoswitching can be specified (value=4).None TRANSLATABLE= true
MappingStringsstringMIF.DMTF|Power Supply|004None None
ValueMapstring1, 2, 3, 4, 5, 6None None
ValuesstringOther, Unknown, Manual, Autoswitch, Wide Range, Not ApplicableNone TRANSLATABLE= true

Inherited Properties

NameData TypeClass Origin
Availabilityuint16CIM_LogicalDevice
CaptionstringCIM_ManagedElement
CreationClassNamestringCIM_LogicalDevice
DescriptionstringCIM_ManagedElement
DeviceIDstringCIM_LogicalDevice
ErrorClearedbooleanCIM_LogicalDevice
ErrorDescriptionstringCIM_LogicalDevice
InstallDatedatetimeCIM_ManagedSystemElement
LastErrorCodeuint32CIM_LogicalDevice
MaxQuiesceTimeuint64CIM_LogicalDevice
NamestringCIM_ManagedSystemElement
PowerManagementSupportedbooleanCIM_LogicalDevice
PowerOnHoursuint64CIM_LogicalDevice
StatusstringCIM_ManagedSystemElement
StatusInfouint16CIM_LogicalDevice
SystemCreationClassNamestringCIM_LogicalDevice
SystemNamestringCIM_LogicalDevice
TotalPowerOnHoursuint64CIM_LogicalDevice