Name | Data Type | Qualifiers |
Name | Data Type | Value | Scope | Flavors |
AddressIdentifier | uint32 |
Description | string | An address value used to identify the source (S_ID) or destination (D_ID) of a frame. The FC-SW standard includes a table of special address identifier values and their meanings. Consult the FC-SW documentation for additional information. | None | TRANSLATABLE= true |
BypassedState | uint16 |
Description | string | Indication of whether the Port is currently bypassed (value=2) or not (value=1). A value of 3 ("Forced Insert") describes that the Port is forced active, when it would otherwise be "Bypassed". | None | TRANSLATABLE= true |
Values | string | Unknown, Not Bypassed, Bypassed, Forced Insert | None | TRANSLATABLE= true |
ConnectedMedia | uint16 |
Description | string | The type of cabling as sensed by the Port. Not all FibrePorts are capable of providing this information. In this case, a value of 0, "Unknown", will be returned. Also, when single or multi-mode fiber cabling can not be distinguished, the more general value - 4, "Fiber-optic" - can be specified. | None | TRANSLATABLE= true |
Values | string | Unknown, Other, No Media, Copper/Twinaxial, Fiber-optic, Fiber Single Mode, Fiber Multimode | None | TRANSLATABLE= true |
CRCErrors | uint64 |
Counter | boolean | true | None | None |
Description | string | Number of times that the CRC in a frame does not match the CRC computed by the receiver. | None | TRANSLATABLE= true |
CurrentPortType | uint16 |
Description | string | The specific mode in which the Port is currently running. The value is one of the entries in the EnabledPortTypes array. The current port type/mode is dependent on the fibre technology. For example, in a public loop network, you might indicate a port type of "FL" (value=6) or "NL" (value=2). | None | TRANSLATABLE= true |
ModelCorrespondence | string | CIM_FibrePort.EnabledPortTypes, CIM_FibrePort.CurrentVersion | None | None |
Values | string | Unknown, N, NL-Private, NL-Public, E, F, FL, B | None | TRANSLATABLE= true |
CurrentVersion | string |
Description | string | Version information for the CurrentPortType that is active. | None | TRANSLATABLE= true |
ModelCorrespondence | string | CIM_FibrePort.CurrentPortType | None | None |
ElasticityBufferOverruns | uint64 |
Counter | boolean | true | None | None |
Description | string | The number of times that a fill word could not be deleted, when required. The Elasticity Buffer is defined in FC-AL. This event might cause data corruption and may indicate a configuration error or a device out of spec. | None | TRANSLATABLE= true |
ElasticityBufferUnderruns | uint64 |
Counter | boolean | true | None | None |
Description | string | The number of times that a fill word could not be inserted, when required. The Elasticity Buffer is defined in FC-AL. This event might cause data corruption and may indicate a configuration error or a device out of spec. | None | TRANSLATABLE= true |
FramesTooLong | uint64 |
Counter | boolean | true | None | None |
Description | string | The number of frames received that were longer than 2140 octets. The value of 2140 is calculated based on an assumption of 24 header bytes plus 4 CRC bytes and 2112 bytes of payload. | None | TRANSLATABLE= true |
FramesTooShort | uint64 |
Counter | boolean | true | None | None |
Description | string | The number of frames received that were shorter than 28 octets. The value of 28 is calculated based on an assumption of 24 header bytes plus 4 CRC bytes. The count does not include SOF/EOF bytes which are not data. | None | TRANSLATABLE= true |
InvalidTransmissionWords | uint64 |
Counter | boolean | true | None | None |
Description | string | The number of transmission words that had an 8b10b code violation in one or more of its characters, had a K28.5 in its second, third or fourth character positions, and/or was an ordered set that had an incorrect Beginning Running Disparity. | None | TRANSLATABLE= true |
LossOfSignalCounter | uint64 |
Counter | boolean | true | None | None |
Description | string | Number of times that signal is lost on the Port since last reset of the Device. | None | TRANSLATABLE= true |
LossOfSyncCounter | uint64 |
Counter | boolean | true | None | None |
Description | string | Number of times that synchronization is lost on the Port since last reset of the Device. Synchronization is assumed lost after a timeout period identified by the ReceiverTransmitterTimeout property. | None | TRANSLATABLE= true |
ReceiverTransmitterTimeout | uint64 |
Description | string | Timeout value in milliseconds used to determine when loss of synchronization has occurred. The typical default is 100 msec. | None | TRANSLATABLE= true |
Units | string | Milliseconds | None | TRANSLATABLE= true |